Simulation Stats

Test Case Name
axial-fan-optimization
Number of Points [ – ]
1
Machine Type
fan
Number of Components [ – ]
(topology)
3
Mesh Size [ cells ]
(details)
inlet : 98403
rotor : 968969
outlet : 146883
Total : 1214255
Average y+ at walls [ – ]
details
Wall-clock time [ hh:mm:ss ]
00:03:24 (meshing)
00:11:03 (calculation)
Parallel Processors [ – ]
24
Fluid Name
air
Physical Model
incompressible
Numerical order
second
Turbulence model
kOmegaSST

Fan Characteristic

1:inlet — 3:outlet
Point Nr.
Flow number [ – ]
Compression number [ – ]
1
0.194616
0.111267

Efficiency

1:inlet — 3:outlet
Point Nr.
Flow Rate [ m3/s ]
Efficiency [ – ]
1
1.40000
0.463040

Torque

Point Nr.
Torque [ N.m ]
1
1.88586

Axial Force

Point Nr.
Axial Force [ N ]
1
-25.3511

Radial Force

Point Nr.
Radial Force [ N ]
1
0.0569709

Power

Point Nr.
Power [ W ]
1
293.467

Total Pressure Difference

1:inlet — 3:outlet
Point Nr.
Flow Rate [ m3/s ]
Total Pressure Difference [ Pa ]
1
1.40000
97.0388