Simulation Stats

Test Case Name
BANCIII-case3-final-case
Number of Points
1
Number of Observers
2
Acoustic Analogy
FfowcsWilliamsHawkings
Analogy Formulation
Farassat1A
Acoustic Source
CFDSimulation
Number Of Source Surfaces
1
Sampling Frequency [ Hz ]
20000
Nyquist Frequency [ Hz ]
10000

Observer summary

ID
Observer Name
Position
Virtual observers
Overall Sound Pressure Level [ dB ]
Play sound
1
Main-BANCIII-Observer-1
(0.4 1 0.02)
no
61.395
2
Circular-Observers-Distribution-1m-TE
Circular distribution

Unfiltered Signal per Observer

Filtered Signal per Observer

Power Spectral Density per Observer

Row Nr.
Frequency [ Hz ]
Power Spectral Density [ dB/Hz ]
1
44.3190
33.0603
2
20.1450
32.6460
3
648.669
32.6343

Sound Pressure Level per Observer

Row Nr.
Frequency [ Hz ]
Sound pressure level [ dB ]
1
44.3190
40.8741
2
20.1450
40.4597
3
648.669
40.4480

Probes

Probe Nr.
Position
1
(0.3956 0.0011182 0.02)
2
(0.4 0 0.02)
3
(0.4 0 0)
4
(0.4 0 0.04)
5
(0 0 0.02)

Polar plots